![IMG_1548.jpeg](https://static.wixstatic.com/media/bc4c19_b7e26b6be64042069e23dc1825cedf36~mv2.jpeg/v1/fill/w_980,h_735,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_b7e26b6be64042069e23dc1825cedf36~mv2.jpeg)
BIOFUELS RESEARCH
LABORATORY
Bench scale reactor is used to test various process parameters, catalysts and raw materials. The second goal of the laboratory is the quality control of raw materials and products.
LABORATORY INSTRUMENTS
The laboratory is equipped in devices enable the quality control. The laboratory instruments such gas gas chromatograph with MS/FID/TCD detectors, distillation analyzer, XRF analyzer, density meter, Karl Fischer titrator, visibility bath and others allow checking the biofuel and raw materials parameters making it easier to optimize process parameters.
LAB REACTOR
Bench scale reactor is used to test various process parameters, catalysts and raw materials.
​
Reactor parameters:
- max. temperature 380 degrees Celsius
- max. pressure 10 bar
- distillation system and coolers
- additional equipment for biofuel production process (biomass feeder, activated carbon, filter, collecting vessel)
![Biofuel produced at Ekotrend Biofuels Research Facility](https://static.wixstatic.com/media/bc4c19_07698f4b417a4256bcba81e3b35360e1~mv2.jpg/v1/fill/w_484,h_645,al_c,lg_1,q_80,enc_avif,quality_auto/Fuel%202_JPG.jpg)
![Ekotrend Laboratory](https://static.wixstatic.com/media/bc4c19_a5b140501da4463e88ed99f37766366c~mv2.jpeg/v1/fill/w_980,h_735,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_a5b140501da4463e88ed99f37766366c~mv2.jpeg)
![Bench Scale Reactor](https://static.wixstatic.com/media/bc4c19_d61c7794e3c64497be8170c4ded9253a~mv2.jpeg/v1/fill/w_980,h_1307,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_d61c7794e3c64497be8170c4ded9253a~mv2.jpeg)
![Bench Scale Reactor](https://static.wixstatic.com/media/bc4c19_a57b62c46ac9438a87de663f57e08be7~mv2.jpeg/v1/fill/w_980,h_1307,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_a57b62c46ac9438a87de663f57e08be7~mv2.jpeg)
![Laboratory Instruments](https://static.wixstatic.com/media/bc4c19_bf7c2adc9a6d4f259e79fd2c2779e335~mv2.jpeg/v1/fill/w_980,h_735,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_bf7c2adc9a6d4f259e79fd2c2779e335~mv2.jpeg)
![Laboratory Instruments](https://static.wixstatic.com/media/bc4c19_56f8ef4a44b84b2c861c438217a226c4~mv2.jpeg/v1/fill/w_980,h_735,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_56f8ef4a44b84b2c861c438217a226c4~mv2.jpeg)
![Gas chromatograph](https://static.wixstatic.com/media/bc4c19_5ca172c1ed1b43ee950d47e3a583f1ad~mv2.jpeg/v1/fill/w_980,h_735,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/bc4c19_5ca172c1ed1b43ee950d47e3a583f1ad~mv2.jpeg)